● General areas of application are industrial burners or the highest safety
class SIL3 as well as marine burners.
● Standards & Certifications:
● Flame signal indicator for multi-color LED signal lights
● The flame signal is displayed by DC 0~10V output signal (display only)
● Parameters can be set through BCI communication interface
● Potential-free signal contacts with protective insulation
● Low voltage monitoring
● Operating voltage: AC 230V, -15%/+10%
AC 120V,-15%/+10%
● Power consumption 5VA
● Protection category I. According to DIN EN 60730-1: Protection category I for use without safety isolation devices. Prevent electrocution risk by double or
reinforced isolation. Connect the safety leads inside the socket AGK11.7.
When replacing LAE10/LFE10 with KF8896 and LFS1, the maximum protection category I II can be achieved for use with safety isolation devices. Prevent the
risk of electric shock by double or reinforced isolation.
● IP40 degree of protection
● Software level Level C according to DIN EN 60730-2-5 2-channel construction
● Flameout identification time max. 1 s for LFS1 (including flame detector)
● Flame-out reaction time max. 1 s for LFS1 with LEC1
● The minimum self-test frequency of the flame monitor is 2x per second for the continuous operation of the ion rod or RAR9
● Operating environment Operating standard EN 60721-3-3:1995 + A2:1997
Climatic conditions Grade 3K5
Mechanical Condition Class 3M2
Temperature range -20...+60°C
Humidity <95%r.F.
● Service life: 250,000 starts in normal operation mode.